C22F  IEC Appliance Inlet C22 for hot Conditions, with Filter for high Temperatures, front side Mounting

Series: C22F

IEC Appliance Inlet C22 for hot Conditions, with Filter for high Temperatures, front side Mounting

Free Sample Request

14 Variants


Connectors (Inlets/Outlets)

C22
Connector Logo
155° C

Description

  • Panel mount: Screw-on from front side
  • 2 Functions: Appliance Inlet Protection class I, Line filter in standard and medical version
  • Solder / quick connect / wires (stranded)

Unique Selling Proposition

  • For higher temperatures
  • Attractive flat front design
  • Highly resistant since fully potted
  • Various filter variants

Characteristics

  • Compact design with optimal shielding
    Suitable for high ambient temperatures up to 75°C
  • Version with class X1 and X2 (standard version) capacitors
  • Universal line filter for standard applications
  • Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP)
    For applications according IEC/UL 62368-1 we recommend variants with bleed resistor

Other versions on request

  • flexible wire with various lenghts

Ratings IEC

16 A @ Ta 75 °C / 250 VAC; 50 Hz

Ratings UL/CSA

20 A @ Ta 65 °C / 250 VAC; 60 Hz

Leakage Current

standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)

Dielectric Strength

> 1.7 kVDC between L-N (Cy2)
> 2.7 kVDC between L/N-PE (Cy2)
Test voltage (2 sec)

Impulse Withstand Voltage

> 2.5 kV between L-N (CX2)
> 4 kV between L-N (CX1)
> 5 kV between L/N-PE (Cy2)
voltage (1.2/50 μs)

Allowable Operation Temperature

-25 °C to 100 °C

Climatic Category

25/100/21 acc. to IEC 60068-1

IP-Protection

front side IP40 acc. to IEC 60529

Protection Class

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Solder / quick connect / wires (stranded)

Panel Thickness S

Screw: max 8 mm
Mounting screw torque max 0.5 Nm

Material

Thermoplastic, black, UL 94V-0

Appliance inlet/-outlet

C22 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for hot conditions) pin-temperature 155 °C, 16 A, Protection Class I

Line Filter

Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8
Technical Details

MTBF

> 1'400'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: C22F

Approval Logo Certificates Certification Body Description
Approval marks ENEC 10 VDE Certificate Number: 104884
Approval marks cURus UL UR File Number: E72928


Product standards

Product standards that are referenced

Organization Design Standard Description
Approval marks IEC Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Approval marks IEC Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Approval marks IEC Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Approval marks UL Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Approval marks UL Designed according to UL 1283 Passive filters for suppressing electromagnetic interference
Approval marks CSA_Group Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Approval marks CSA_Group Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Approval marks IEC Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements
Approval marks IEC Suitable for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Approval marks Zulassung_Symbol_UKCA SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP)

020060160000001653
LOADING...

Dimension [mm]

Screw-on mounting with quick connect terminals

Screw-on mounting with wire leads


Diagrams

Standard version

1) Line
2) Load
Medical Version (M5)

1) Line
2) Load

Technical Data of Filter-Components

Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ]
16 Standard version 2 x 0.6 100 2.2 1
16 Standard version 2 x 0.6 330 2.2 1
20 Standard version 2 x 0.3 100 2.2 1
20 Standard version 2 x 0.3 330 2.2 1
16 Medical Version (M5) 2 x 0.6 100 - 1
20 Medical Version (M5) 2 x 0.3 100 - 1
20 Medical Version (M5) 2 x 0.3 330 - 1
16 Medical Version (M80) 2 x 0.6 100 0.47 1
20 Medical Version (M80) 2 x 0.3 100 0.47 1

Attenuation Loss

16 A

20 A

16 A

20 A

16 A

20 A


Short Table of Variants C22F Open complete table C22F

Rated Current IEC [A] Rated Current UL [A] Filter-Type Order Number A=Most Popular Free Sample Distributor Stock Check ...
                     
 
16 16 Standard version C22F.1107 ...
16 20 Standard version C22F.0101 ...
16 16 Standard version C22F.1101 ...
16 20 Standard version C22F.0103 ...
16 20 Standard version C22F.0007 ...
16 20 Standard version C22F.0001 ...
16 16 Standard version C22F.1001 ...
16 20 Standard version C22F.0003 ...
16 20 Medical Version (M5) C22F.0102 ...
16 16 Medical Version (M5) C22F.1102 ...
16 20 Medical Version (M5) C22F.0008 ...
16 20 Medical Version (M5) C22F.0002 ...
16 16 Medical Version (M5) C22F.1002 ...
16 16 Medical Version (M80) C22F.1005 ...

Packaging unit 20 Pcs 

020060160000001653
LOADING...
Alternative: version without line filter (1)

[Swipe to the left and right for more options]

Mating Outlets/Connectors (2)

[Swipe to the left and right for more options]

1658.0000

1658, Mounting: Power Cord, Screw clamps Connector: IEC C21

6051.5001

Cord Sets 16 A, Europlug, 2.5 m, Connector IEC C21, H05VV-F3G1.5, black

Accessories (3)

[Swipe to the left and right for more options]

Wire Harness

Wire harness for SCHURTER products

Assorted Covers

Rear Cover

RC320

Rear Cover for Power Entry Module


16.05.2024
   
en prod By changing the catalog version (Desktop <> Mobile), the system is resetting the chosen filters